1
1451 Belcher Road South, Largo, FL 33773 • USA
• Tel +1 (727) 447-6140 • Fax (727) 442-5699 •
[email protected]F-2600 & F-2700 Vortex Flow Meter Manual 02/15 - 0808-7 / 19204 Page 102
• TOF, G, f = Factory use only
• Sig. Rev = Signal board hardware and rmware revision
• Miro Rev = Microprocessor board hardware and rmware revision
• AD, R, T, F, PT, V = Factory use only
• SPI Err, Rcv, Sent = Factory use only
5.5.2 LEVEL TWO HIDDEN DIAGNOSTICS VALUES
• 4-20(1) Zero = Analog counts to calibrate zero on analog output 1.
• 4-20(1) FScale = Analog counts to calibrate full scale on analog output 1.
• 4-20(2) Zero = Analog counts to calibrate zero on analog output 2.
• 4-20(2) FScale = Analog counts to calibrate full scale on analog output 2.
• 4-20(3) Zero = Analog counts to calibrate zero on analog output 3.
• 4-20(3) FScale = Analog counts to calibrate full scale on analog output 3.
• Ext. 4 mA Cal. = Enter 0 for auto calibration or enter factory supplied A/D counts.
Note: You must connect a known 4 mA input if you are going to calibrate the unit.
• Ext. 20 mA Cal. = Enter 0 for auto calibration or enter factory supplied A/D counts.
Note: You must connect a known 20 mA input if you are going to calibrate the unit.
• External Input = Enter what the external 4-20 mA input represents; i.e. Temperature 1,
Temperature 2, or Pressure. The meter will use this for its internal calculations.
• Ext. Full Scale = Enter the full scale units that correlate to the 20 mA point. Note: It
must be in the units for the selected input type such as Deg F, Deg C, PSIA, Bar A, etc.
• Ext. Zero Scale = Same as above but for the 4 mA point
• Alarm (1) Test = Used as a test to verify that the alarm circuit is functioning. When
Low is selected, the alarm will initiate a low alarm on the output. When High is
selected, it will give a high alarm on the output.
• Alarm (2) Test = Used as a test to verify that the alarm circuit is functioning. When
Low is selected, the alarm will initiate a low alarm on the output. When High is
selected, it will give a high alarm on the output.
• Alarm (3) Test = Used as a test to verify that the alarm circuit is functioning. When
Low is selected, the alarm will initiate a low alarm on the output. When High is
selected, it will give a high alarm on the output.
• Reynolds Corr. = Reynolds number correction for the ow prole. Set to Enable for
F-2700 insertion, and set to Disable for F-2600 inline.
• Gain Control = Manual gain control (factory use only). Leave set at 1.
• Filter control = Manual lter control. This value can be changed to any number to
force the value to a constant. A value of zero activates the automatic lter control
which sets at a level that oats above the f value.
• High Pass Filter = Filter setting – Factory use only
• Factory Defaults = Reset factory defaults. If you change this to Yes and press ENTER,
all the factory conguration is lost and you must recongure the entire program.
Consult the factory before performing this process, it is required only in very rare
cases.
• Meter Type = Insertion or in-line meter
• Cong Code = Factory use only
• Test Pulse Out = Force totalizer pulse. Set to Yes and press ENTER to send one pulse.
Very useful to test totalizer counting equipment.
• Test Scaled Freq = Enter a frequency value in order to test the scaled frequency
output. Return to 0 to stop the test.
Comentarios a estos manuales